Fused spur on ring main

WebAug 19, 2024 · My first option is to extend the ring main using Jb. My second option is to use a fused spur for the 2 additional sockets. The first option will involve lifting laminated floors and then floor boards and possible drilling through joist. The second option also involves the same scenario,but slightly less work. WebJan 22, 2014 · Tuesday 21st January 2014. The maximum load you can run from a spur is 13A (Approx 3kW). If the socket is spurred dircetly form the ring (with no fused connection unit) then is should only consist ...

electrical - How best to add sockets to a fused spur? - Home ...

WebMar 1, 2016 · ring main socket behind a washing machine. hi, i am planning on installing a new work counter in my kitchen underneath which will be a washing machine and tumble … WebIt's more of a regulation thing - your ring main CB (32A) is rated higher than the cable (27A max) but the current can go two ways - in a spur it can only go one way so the cable isn't fully protected against over current by the CB - hence a fused spur is the answer. The UK is awash with spurs off spurs. culver city high school yearbooks https://jasoneoliver.com

Fused Spurs Buying Guide - Types and Applications - RS Compon…

WebYou can have one unfused spur per socket-outlet on a ring main or one fused spur per socket-outlet, you can have as many sockets as you like off of a fused spur. Share this answer: Not what you were looking for? Submit a question to our team and we’ll get back to you as soon as possible. You’ll be notified by email once your question has ... WebMay 29, 2024 · As long as the job isn’t within a ‘special location’ such as a bathroom or outdoors, you’re also allowed to install additional new light fittings, switches, sockets and even add a single fused spur to an existing circuit (a ‘spur’ is a new cable and socket run as a branch from an existing socket on the ring main). culver city hiking

Lighting circuit off a fused spur DIYnot Forums

Category:Can you use a 20 Amp double pole switch to control a spur from a …

Tags:Fused spur on ring main

Fused spur on ring main

16 Amp for ring main (plugs) DIYnot Forums

WebIn kitchens, it's often desirable to be able to control a hidden 13A socket outlet remotely. For example when the socket is behind a washing machine or dishw... WebIf the circuit was originally a ring main but this has become broken and is now a spur or radial main then it could be fed with 2.5mm and 32 amp fuse. Use a multi-meter to test for a radial or ring main (final ring circuit) …

Fused spur on ring main

Did you know?

WebOct 8, 2024 · Ring circuit with spurs. Branches know as spurs may be taken off the ring from any socket or by breaking into one of the cables of the ring. They can either be … WebThe spur can be taken from any socket or FCU within the Ring Main circuit. The spur not only supplies a socketbut may supply FCU`s as well. The rule is that you can spur off one socket from a point within a Ring Main …

WebMatt is on site wiring a spur from a ring final circuit. Matt is using PVC mini trunking and 2.5 mm2 cable to wire a spur socket from an A1 ring final circui... http://www.sparkyfacts.co.uk/Wiring-Diagrams-Ring-Circuit-Wiring.php

WebFeb 18, 2024 · 2024 new build house. Detached garage supplied by a fused spur from house ring main by 2.5mm 3 core SWA (Mostly underground). The fused spur unit was inside the garage. One light inside, one double socket and one exterior pir floodlight. Had an electrician in to add: a single exterior socket and two exterior LED lights. WebOct 12, 2024 · Discuss Fused spur off ring main regulations in the Electrical Courses and Electrical NVQ's area at ElectriciansForums.net. 1; 2; 3; Next. 1 of 3 Go to page. Go. ... if …

Webchristoy123 • 1 yr. ago. Yeah basically a fused spur means you can add as many sockets as you like after it as the fuse protects the cable. Only downside would be if you run too much power it could nuisance trip the fuse which is annoying but shouldn’t be dangerous. You can add as many fused spurs off the ring as you like and you can spur ...

WebApr 7, 2024 · I have underlined the things to reconsider:-Ring main circuit 2.5mm T+E 14 twin socket outlets in total (obviously not all used at once - more convenience as i hate extension cords) 12 of which are on the ring main.1 TSO is external and has a fused spur internally (from a socket on the ring) to isolate it should i wish. east of chicago brunswick ohioWebNov 9, 2024 · Reaction score. 510. Country. 9 Nov 2024. #2. You need to check the size of the cables used, i.e. the diameter of the copper. It’s likely it’s too thin to supply 32A, hence the 16A fuse. The circuit doesn’t need to loop back to the fuse board - what you have is called a “radial” circuit. culver city hiking clubsWebFeb 8, 2024 · In my flat I have a spur from the ring main to two double plug sockets either side of the bed. There is a 13amp fused spur switch between the ring main and the spur. I want to extend the spur to go to 2 wall lamps (they have a on/off switch in the base). east of chicago dealsWebThere are three ways of adding a socket outlet to a ring circuit. The most common is to connect it as a spur, and this can be done in two ways. Alternatively, the ring can be extended. Spur from existing socket outlet … culver city historical society and archivesWebFeb 7, 2024 · Ive tested a ring main in a house with RCD protection, the results ive had are L-L .43 ... they have a fuse spur fed from one of the sockets and then have 6 x double sockets after the fuse spur. The last 3 are out door and the last socket on the ‘radial’ gives a Zs reading of 1.64. culver city hiking stairs biWebSep 28, 2024 · Hi .In this video I,m showing how to make a light spur from socket outlet that's on ring circuit. Hope it helps. Please Subscribe culver city hikeWebOct 23, 2024 · The ring main services two small rooms only (not the kitchen) and has bags of capacity. My query is simply this: The electrician has used 2.5mm cable for the spur. The spur is only about 1m long, and I realise this is more than capable of feeding the 1.9kW load, but I expressed surprise because this won't be protected by the MCB which is 32A. east of chicago cuyahoga falls